1.Automatically controlled the sterilizing process, easy to operate.
2.With drying function, suitable for the medical dressing drying.
3.With over-temperature, over-pressure auto-protect.
4.The door can not be open until the pressure in the chamber is reduced to0.027MPa. And the unit can’t be started on if the door doesn’t close well.
5.The safety value will be open automatically when the inner pressure over0.24MPa, and the steam would be exhausted the water tank.
6.Automatically cut off the power if the water-lack happened, and alarm atthe meanwhile.
7.The chamber of the sterilizer is made of stainless steel.
8.With printer.
Technical data | LPWS-150YDB | LPWS-200YDB | LPWS-280YDB |
Sterilizing chamber | 150L | 200L | 280L |
volume | φ440×1000mm | φ515×1000mm | φ600×1000mm |
working pressure | 0.22 MPa | ||
working temperature | 134℃ | ||
Adjustment of temperature | 105℃ – 134℃ | ||
Time of sterilization | 0-99 min | ||
Time of drying | 0-99 min | ||
Heat average | ≤± 2℃ | ||
Power | 9KW/380V 50Hz | 9KW/380V 50Hz | 12KW/380V 50Hz |
Dimension | 1400×650×1600 | 1400×750×1700 | 1520×910×1900 |
Transport dimension | 1560×820×1820 | 1560×910×1880 | 1680×1080×2100 |
G.W/N.W | 430/340 KG | 436/350 KG | 570/462 KG |
Why Autoclave is The Best Method of Sterilization
Autoclaving stands out as a highly effective method of sterilization for several reasons: 1.Comprehensive Microbial Elimination: Autoclaves use high-pressure steam, typically at temperatures above 121°C
Why is autoclaving done for 15 minutes?
The reason high-pressure sterilization typically takes 15 minutes or more is to ensure the thorough elimination of various microorganisms, including bacteria, viruses, fungi, and spores.
How an Autoclave Works
The high-pressure sterilizer functions based on a fundamental principle that leverages elevated temperature and pressure to achieve potent disinfection. Here’s a simplified explanation of its
How to clean autoclave monthly
Regularly cleaning and maintaining the high-pressure sterilizer each month is essential to ensure its proper functioning and effectiveness in disinfection. Here are the general steps
How Does an Autoclave Work
A high-pressure sterilizer operates by placing objects within a sealed chamber and introducing high-temperature, high-pressure steam. The working process can be summarized in the following
What is Autoclave Sterilization
High-pressure sterilization is a process that utilizes high-pressure steamand elevated temperatures to eliminate microorganisms on the surface and withinan object. In this procedure, the object